ITF is found in SCIENCE. MAINTENANCE IN PROGRESS
At 6:01 UTC I set the ITF in Maintenance Mode, here is the list of the activities communicated to the Control Room:
- Cleaning of Central Building, Laser Lab (external firm managed by Gargiulo);
- VAC Refill (Vacuum Team);
- 6:30 UTC Refill TCS chillers and change the filter of the aux cooling system (N. Menzione and J. Gargiulo)
- Operator Periodic Tasks (see section below);
- check of magnetometers at CEB (I. Fiori, M, Graziaplena)
- F. Sorrentino DET SQZ box alignment
- D. Soldani checks AHU DET,INJ, CEB
- 08:34-08:40 UTC replacement of WI etalon power supply (R. Cavalieri, V. Dattilo)
- 09:10-09:48 and 09:50-10:20 UTC FSR scan with 4 times the normal iterations value
- DMS flags added to horizontal positions SBE benches (H. J. Bulten)
- upgrades on the underlaying virtual infrastructure where the fileserver are hosted (E. Kraja, S. Cortese)
- D. Lumaca tuned the CO2 and DAS
- DT turbo pump cooling fan replacement (Vacuum team)
Periodic Tasks carried out by the Operator:
- From 6:19 UTC to 6:36 UTC, Check of IMC Working Point and Position;
- 07:04-07:09 UTC OMC locked in SINGLE_BOUNCE_NI
- From 7:11 UTC to 7:32 UTC - OMC Scan in Single Bounce configuration;
- At 8:00 UTC - TCS Thermal Camera Reference;
- At around 06:23 - 06:35 UTC - TCS Power Checks (see table below for results):
CH (W) | Inner DAS (W) | Outer DAS (W) | |
W Pickoff | 0.255 | 0 | 0.22 |
N Pickoff | 0.68 | 0.065 | 0.602 |
11:25 UTC Maintenance ended, I re-aligned the CITF and relocked the ITF at the first attempt, back in SCIENCE at 11:35 UTC.
11:58 UTC Vpm restarted